HF6002-17P+HF608: | |
---|---|
Availability: | |
Quantity: | |
HF6002-17P+HF608
FOFO
9019.1010
1.Applicability: Suitable for hospital and home care Settings.
2.Bedsore treatment: The A-B line alternate airbag design provides super bedsore treatment.
3.Material: Use medical grade PVC material from Taiwan Nanya Company, durable and high quality.
4.Welding technology: One-time welding by 200KW power high frequency machine to ensure air tightness.
5.Output: 2000 pieces of air cushion bed can be produced daily.
6.Warranty: The mattress comes with a 1-year warranty.
1.Applicability: Suitable for hospital and home care Settings.
2.Bedsore treatment: The A-B line alternate airbag design provides super bedsore treatment.
3.Material: Use medical grade PVC material from Taiwan Nanya Company, durable and high quality.
4.Welding technology: One-time welding by 200KW power high frequency machine to ensure air tightness.
5.Output: 2000 pieces of air cushion bed can be produced daily.
6.Warranty: The mattress comes with a 1-year warranty.
1.Preparation: Lay the air mattress on a solid bed frame or flat surface, ensuring that no sharp objects may damage the air mattress.
2.Connection: The air nozzle of the air cushion bed is connected to the air outlet of the air pump.
3.Power supply: Make sure the air pump is connected to 110V/220V power supply at a frequency of 50-60Hz.
4.Inflate: Turn on the air pump and start to inflate the air mattress. During the inflation process, watch the air mattress expand to the appropriate pressure.
5.Adjustment: According to the needs of patients, adjust the air output of the air pump to ensure that the air mattress reaches the appropriate hardness and comfort.
6.Place the patient: After the air mattress has been inflated to the appropriate pressure, the patient is carefully placed on the air mattress.
7.Monitoring: Regularly check the pressure of the air mattress and the patient's skin condition to ensure that the air mattress is working properly and the patient does not have bedsores.
8.Emergency: If rapid venting is required, the CPR valve can be used.
9.Maintenance: After use, clean the surface of the air mattress to ensure that there is no dirt or moisture. Follow the manufacturer's cleaning and maintenance guidelines.
10.Storage: When not in use for a long time, deflate the air and store the air mattress and pump according to the manufacturer's instructions.
11.Note: The air mattress is fire and water resistant, and the material is certified by SGS to ensure the safety and durability of the product.
1.Preparation: Lay the air mattress on a solid bed frame or flat surface, ensuring that no sharp objects may damage the air mattress.
2.Connection: The air nozzle of the air cushion bed is connected to the air outlet of the air pump.
3.Power supply: Make sure the air pump is connected to 110V/220V power supply at a frequency of 50-60Hz.
4.Inflate: Turn on the air pump and start to inflate the air mattress. During the inflation process, watch the air mattress expand to the appropriate pressure.
5.Adjustment: According to the needs of patients, adjust the air output of the air pump to ensure that the air mattress reaches the appropriate hardness and comfort.
6.Place the patient: After the air mattress has been inflated to the appropriate pressure, the patient is carefully placed on the air mattress.
7.Monitoring: Regularly check the pressure of the air mattress and the patient's skin condition to ensure that the air mattress is working properly and the patient does not have bedsores.
8.Emergency: If rapid venting is required, the CPR valve can be used.
9.Maintenance: After use, clean the surface of the air mattress to ensure that there is no dirt or moisture. Follow the manufacturer's cleaning and maintenance guidelines.
10.Storage: When not in use for a long time, deflate the air and store the air mattress and pump according to the manufacturer's instructions.
11.Note: The air mattress is fire and water resistant, and the material is certified by SGS to ensure the safety and durability of the product.
Specification parameters:
Mattress (HF6002-17P) :
Dimensions: Not explicitly provided, but usually consistent with standard hospital bed dimensions.
Air chamber: 17 air chambers.
Pressure range: 50-120mmHg.
Cycle time: 12 minutes.
Bottom material: welded tarp.
Weight: 5-5.5kg.
Load-bearing capacity: 135kg.
Air pump (HF608) :
Power supply: 110V/220V, 50-60Hz.
Air output: 5-7 L/min.
Power consumption: 7W.
Fuse: 1A.
Size: 27.5cm(L) × 13.5cm(W) × 9cm(H).
Weight: 1.6kg.
Specification parameters:
Mattress (HF6002-17P) :
Dimensions: Not explicitly provided, but usually consistent with standard hospital bed dimensions.
Air chamber: 17 air chambers.
Pressure range: 50-120mmHg.
Cycle time: 12 minutes.
Bottom material: welded tarp.
Weight: 5-5.5kg.
Load-bearing capacity: 135kg.
Air pump (HF608) :
Power supply: 110V/220V, 50-60Hz.
Air output: 5-7 L/min.
Power consumption: 7W.
Fuse: 1A.
Size: 27.5cm(L) × 13.5cm(W) × 9cm(H).
Weight: 1.6kg.